Catalina Apartments (Mounts Bay Road, Nedlands, Perth WA)

Project: Supply and Install a fully addressable Fire Detection (7 loop) system with a 12 zone EWIS system.

This site was completed and has been operational since July, 2004 with the following configuration:

Main FIP Notifier Inertia AFP2800, Brigade Connected.

602 Smoke Detectors
118 Heat Detectors
36 Other system interfacing devices
348 Speakers
         

 

Commercial
Fisheries Research Facility (Hillarys, Perth WA)

Project: Supply and Install a fully addressable Fire Detection (2 loop) system with two 50W amplifiers for the occupant warning.

This site was completed and has been operational since March, 2005 with the following configuration:

Main FIP Notifier Inertia AFP2800, Brigade Connected.

293 Smoke Detectors
3 Heat Detectors
19 Other system interfacing devices
86 Speakers

 

Commercial

Stirling Civic Centre (Stirling, Perth WA)

Project: Supply and Install a fully addressable Fire Detection (7 loop) system with a zone EWIS system.

This site was completed and has been operational since March, 2005 with the following configuration:

Main FIP Notifier Inertia AFP2800, Brigade Connected.   

602 Smoke Detectors
118 Heat Detectors8
36 Other system interfacing devices
348 Speakers

 

 

Police Operations Centre “Cadcom” (Midland, Perth WA)

Project: Design, supply and install a fully integrated Fire Detection system, EWIS System and five FM200 suppression systems through the complex.  All systems were third party tested and certified for full compliance to the relevant Australian Standards.

A full room integrity test and agent drop test was conducted in the large computer room with the FM200 (160kg) bottle.  The room net volume was 270m3.

This site was completed and has been operational since June, 2001 with the following configuration:

Main FIP Siemens CS1140 “Cerberus Algorex” networked to two remote mimic consoles.  An integral seven zone EWS was also incorporated in the main panel enclosure. Brigade Connected.

2 Addressable Loops
215 Smoke Detectors
11 Thermal Detectors
21 Aspirating Systems
69 Speakers
5 FM200 Systems

 

 

Campbell Barracks Special range Complex (Swanbourne, Perth, WA)

Project: Design, supply and install a fire Detection system to suit the harsh environment of a shooting complex.  Designed for the detection the VESDA systems networked and low level interfaced to a new Fire Alarm panel.  The main design feature of this system was the design of a specially manufactured stainless steel sampling point that could handle the hit of a bullet during shooting drills.

This site was completed and has been operational since June, 2003 with the following configuration:

Main FIP Notifier Inertia AFP2800, Brigade Connected.

9 Vesda Units on the Vesdanet
57 Smoke Detectors
94 Heat Detectors

 

Commercial
Wesfarmers Office Building – Murdoch University campus (Murdoch, Perth WA)

Project: Supply and Install a fully addressable Fire Detection system with an integral EWIS system.

This site was completed and has been operational since February, 2006 with the following configuration:

Main FIP Notifier Inertia AFP2800 (2 loop)/I2000 combination EWS (8 zone) system, Brigade Connected.

165 Smoke Detectors
16 Heat Detectors
1 Vesda
70 Speakers
18 Visual Lights
7 Warden Intercom Phones